steel braid burst failures ..had any?

Dolly Llama

Number 5
Joined
Oct 7, 2006
Messages
31,225
Location
North East Ohio
Name
Larry Capitoni
some here have never had one.
I had several in the three years I used it

fortunately no was burnt and no messes that couldn't be corrected
butt.......

..L.T.A.
 
  • Like
Reactions: BIG WOOD

steve_64

Member
Joined
Aug 11, 2012
Messages
13,372
KIMG0738.jpg
Not yet but my auxillary solution fitting was leaking and when I took it apart all three nipple were broke. It would've blasted me in the chest had they blown.

I capped them off instead of putting the qd back on.
 

Cleanworks

Moderator
Joined
Oct 22, 2012
Messages
27,863
Location
New Westminster,BC
Name
Ron Marriott
I've had it happen on a very high heat unit I used to own. Used to get up to 280 f at the truck. Taught me to regularly cut of the ends and a foot of hose and put new ends on it. Inspect your hoses at your ends and replace as soon as it seems to be a little soft. Use hose protectors at both ends. I have never had a hose burst in the middle anywhere.
 
Joined
Oct 7, 2006
Messages
18,851
Location
Benton KY USA
Name
Lee Stockwell
When I was in the hospital my daughter and SIL had a bad one. TX tm with no heat control. Had to open side valve on wand to lower heat, they misjudged. Nobody hurt, 200 cleanup.
 

BIG WOOD

The Timminator
Joined
Feb 4, 2016
Messages
14,080
Location
Georgia
Name
Matt w.
One time in my early idiocy. It was an awakening to replace every year
 
Joined
May 16, 2010
Messages
1,191
Name
Noble Carpet Cleaners
When I ran propane heat my last TM I would blow steel braided from time to time. Then every six months I started moving the 1st 50 ft section (next to the wand) back 50' and the last section I toss. Never had a problem since.
 

Mike Draper

Member
Joined
Jan 13, 2008
Messages
4,402
I should say that expensive plastic crap failed on me within a month of buying it every time.
 

BIG WOOD

The Timminator
Joined
Feb 4, 2016
Messages
14,080
Location
Georgia
Name
Matt w.
I should say that expensive plastic crap failed on me within a month of buying it every time.
Can you be specific? Are you talking about par flex or another brand? You're the first one I've seen to complain about the plastic braided kind
 
Joined
May 16, 2010
Messages
1,191
Name
Noble Carpet Cleaners
"a steady diet of 240" See, that's the what gets lost in translation in this biz. I had two 50' sections of Parflex that got 240-250 ATM with no fluctuation and one of them failed (at the machine) after approx 1 month; 240-250 degrees and 500 psi. On commercial tile jobs I blew brand new Goodyear steel braided with 250 degrees and 1,200-1,300 psi. It's not junk hose, just not engineered for high temp continuous and 1k psi and above. For a year on my commercial tile I went to 3/8" high temp pressure washer hose and my problems went away. I'm sure everyone experiences something different but a will say that average truck mounts don't stay max'd out at their rated temps (like 220-240) especially when you start hopping on the triggers whether it be wands or rotaries.
 
  • Like
Reactions: Dolly Llama

Dolly Llama

Number 5
Joined
Oct 7, 2006
Messages
31,225
Location
North East Ohio
Name
Larry Capitoni
BTW, I'm not saying Parker can't or hasn't failed .
Just that's it's not instant without waning or potentially catastrophic
Gives LOTS of warning signs (bubbled jacket, then pin sprays) long before complete failure ...and I've never had one side split like Goodyear


..L.T.A.
 

Jim Williams

Member
Joined
Oct 8, 2006
Messages
1,462
Location
Bynum N.C.
Name
Jim Williams
I've mostly used Continental or Goodyear and never had one bust. Now that I have a propane unit I will definitely be replacing it more than every 4 or 5 years.
 

John Olson

Member
Joined
Oct 9, 2006
Messages
6,281
Location
Orem UT
Name
John Olson
Running high heat (steam way) and not replacing your hose when you knew it and had the brand new one on your front seat but wanted to finish the last few apartments....not me a customer who came in and shared these so I can share them when someone argues that their hoses last several years and I’m just trying to sell new hose
 

Attachments

  • 0235B881-9312-4FCB-B3EB-C29A42A9AFE6.jpeg
    0235B881-9312-4FCB-B3EB-C29A42A9AFE6.jpeg
    311.1 KB · Views: 222
  • 00ABE074-EC73-497A-803A-180008F7A441.jpeg
    00ABE074-EC73-497A-803A-180008F7A441.jpeg
    346.7 KB · Views: 212
  • 44561D5B-4EFF-464C-B340-3E0BA0CFEAF3.jpeg
    44561D5B-4EFF-464C-B340-3E0BA0CFEAF3.jpeg
    378.5 KB · Views: 209
  • Like
Reactions: Mike Draper

Latest posts