Descaling a direct drive??

SamIam

Member
Joined
Aug 9, 2012
Messages
11,094
Location
California
Name
sam miller
I know there Saiger videos for butler!

But does butler wave a water box to add the descaler?

The pro 1200 has no water box !

I know the 570’s water box with the radiator pressure relief cap you lower the water put a gallon or two in the machine and use a loop hose from the intake to the water pressure out!

And kinda sprinkle the descaler into the water box slowly.

Let it run 15 minutes and flush with water 5 minutes and detergent another 3 minutes!

So I’m wondering do you use the chemical jug and use a loop hose on a pro1200?

And just meter it at 10 and let it loop?
 

Jimmy L

Member
Joined
Oct 7, 2006
Messages
15,162
Location
Ne
Name
Jimmy L
On my cleanco I just use that 50/50 vinegar in my solution jug and just open the dwyer valve and suck it all thru my system. Shut it off for about 1/2 an hour and then start it up and let it go thru my solution hoses. Put a little emulsifier in the jug and let that go thru the xchangers and solution hose.
 
  • Like
Reactions: Nomad74

SamIam

Member
Joined
Aug 9, 2012
Messages
11,094
Location
California
Name
sam miller
B85DA1FE-0993-48EA-ABC2-40FDABB38DE4.jpeg
C44A03BF-B4EB-4909-9B54-DBF7F5DB2089.jpeg
D03DF3AF-486B-4854-BD9B-69004825971C.jpeg



Pulled off out bound filter looks pretty clean!
 

cptuphcln

Member
Joined
Oct 31, 2017
Messages
4
Location
Arizona
Name
scott
I know there Saiger videos for butler!

But does butler wave a water box to add the descaler?

The pro 1200 has no water box !

I know the 570’s water box with the radiator pressure relief cap you lower the water put a gallon or two in the machine and use a loop hose from the intake to the water pressure out!

And kinda sprinkle the descaler into the water box slowly.

Let it run 15 minutes and flush with water 5 minutes and detergent another 3 minutes!

So I’m wondering do you use the chemical jug and use a loop hose on a pro1200?

And just meter it at 10 and let it loop?[/QUOTE

There is no water box on the 1200se, so we will have to use an auxiliary pump and a bucket to get the desaler through the system.
Running it through the chemical system will not get it into the system, as this is the last step chemical injection system.
if you need assistance we could be reached at 866-445-3030 ext 4007 Scott
 

cptuphcln

Member
Joined
Oct 31, 2017
Messages
4
Location
Arizona
Name
scott
There is no water box on the 1200se, so we will have to use an auxiliary pump and a bucket to get the desaler through the system.
Running it through the chemical system will not get it into the system, as this is the last step chemical injection system.
if you need assistance we could be reached at 866-445-3030 ext 4007 Scott
 
  • Like
Reactions: SamIam
Joined
Oct 7, 2006
Messages
18,834
Location
Benton KY USA
Name
Lee Stockwell
With the pro 2000 I boost it thru the system by putting an open qc in the solution connection and use the vacuum cuff to pull it thru
 
  • Like
Reactions: SamIam

SamIam

Member
Joined
Aug 9, 2012
Messages
11,094
Location
California
Name
sam miller
There is no water box on the 1200se, so we will have to use an auxiliary pump and a bucket to get the desaler through the system.
Running it through the chemical system will not get it into the system, as this is the last step chemical injection system.
if you need assistance we could be reached at 866-445-3030 ext 4007 Scott

Based on my pictures and user soft water and the outbound filter being clean, do you think I need to worry about yet 950 hours on machine
 

SamIam

Member
Joined
Aug 9, 2012
Messages
11,094
Location
California
Name
sam miller
There is no water box on the 1200se, so we will have to use an auxiliary pump and a bucket to get the desaler through the system.
Running it through the chemical system will not get it into the system, as this is the last step chemical injection system.
if you need assistance we could be reached at 866-445-3030 ext 4007 Scott


I was thinking actually having a loop hose like on the 570 from water inlet to the high pressure outlet and let it loop!
 

cptuphcln

Member
Joined
Oct 31, 2017
Messages
4
Location
Arizona
Name
scott
Based on my pictures and user soft water and the outbound filter being clean, do you think I need to worry about yet 950 hours on machine
A water softener defiantly helps, I have always recommended at least once a year on descaling as a preventative maintenance.
 
  • Like
Reactions: SamIam

Latest posts